TM 9-2350-222-20-2-3-2
28-4.
165-MM THREE ROUND AMMUNITION RACK REMOVAL PROCEDURE
(CONT)
FRAME 1
Step
Procedure
When removing last bolt (1), be careful that rack
assembly does not fall from turret ring. Injury could
result.
1.
Using socket wrench, remove three bolts (1) and six lockwashers (2) that attach
ammunition rack (3) to turret ring (4). Remove rack.
END OF TASK
Para 28-4 Cont
28-9