TM
9-2350-222-20-1-5
PRECLEANER AND GAS PARTICULATE FILTER REPLACEMENT (Sheet 1 of 5)
PROCEDURE INDEX
PAGE
PROCEDURE
Removal
Cleaning and Inspection
Installation
TOOLS: Slip joint pliers
Cross-tip screwdriver
Flat-tip screwdriver
9/16 in. combination box and
7/16 in. socket with 1/2 in. drive
open end wrench
5/16 in. combination box and
9/16 in. socket with 1/2 in. drive
open end wrench
SUPPLIES: Lockwasher (MS35335-31) (2 required) Lockwasher (MS35335-35)
Lockwasher (MS35338-44) (4 required) Lockwasher (MS45904-76)
REMOVAL:
Using pliers, disconnect electrical connector (A) by unscrewing nut (B) on electrical connector.
1.
Using screwdriver, loosen six hose clamps (C)
2.
securing hose and elbow (D) to filter.
If clamps (C) cannot be loosened
with screwdriver, use 5/16 inch
wrench.
3.
Pull elbows (D) and hose out from filter.
4.
Using 9/16 inch wrench, remove bolt (E) and
move shift linkage (F) out of the way.
Go on to Sheet 2
TA139343