TM 9-2350-222-20-1-5
PERSONNEL HEATER REPAIR (Sheet 2 of 8)
Heater Ignitor Replacement (Sheet 2 of 4)
Using screwdriver, turn two captive screws (E)
5.
--
one quarter turn counterclockwise.
6. Move electrical inlet connection (F) aside.
7. Disconnect igniter ground lead (G) (shorter
Disconnect white lead (H) (longer lead) at
igniter control (J).
9 . Push down on ignitor (K). Rotate it about 1/8
turn counterclockwise.
INSPECTION OF IGNITOR WICK:
1.
Using flashlight, look into igniter tube at wick. Yarn should be dry, unbroken, and white.
2.
If strands of yarn seem thin (less than 1/16-inch thick) or are broken, notify support maintenance.
3.
If wick is wet, burner is flooded.
If burner is flooded, go to TEST procedures at end of this task.
4.
If burner is not flooded, go on to INSTALLATION.
5.
Go on to Sheet 3
TA141250
19-25