TM 9-2350-222-20-1-4
SLAVE RECEPTACLE REPLACEMENT (Sheet 2 of 3)
REMOVAL:
1.
Using offset cross-tip screwdriver, remove
cover (C). Throw lockwashers away.
2.
Remove cover (C).
3.
Using 9/16 inch socket, remove two screws
and lockwashers (D) securing cables to
receptacle (E). Throw lockwashers away.
4.
Using 3/8 inch wrench to hold nut (F), use
cross-tip screwdriver and remove four
and nuts (F) securing receptacle (E) and
cover (K) lead to bracket. Throw lock-
washers away.
5.
Remove cover (K), receptacle (E), gasket (M),
and insulator (L) from bracket.
Go on to Sheet 3
TA253362
Change 1 10-417