DUST DETECTOR OPERATIONAL TEST (Sheet 1 of 3)
1/2 in. combination box and open end wrench
TOOL:
SPECIAL TOOLS: Ground hop kit (Item 30, Chapter 3, Section I) if powerplant is out of tank
REFERENCE TM 9-2350-222-10
PRELIMINARY PROCEDURE Open top deck grille doors (TM 9-2350-222-10)
NOTE
q Operational test may be performed with powerplant out of
vehicle if ground hop kit has starter cable modified to accommodate
improved clean air system. If powerplant is out of vehicle, connect
ground hop kit according to procedure on page 5-48.
Operational test is the same for both right and left sides.
1. Remove dust and dirt from filter strip cover (A) and compressor housing (B).
2. Using wrench, loosen three screws (C) securing filter strip cover (A) to compressor
housing (B), but do not remove cover (A).
3. Insert l-inch wide strip of nonporous material (plastic, celluloid, etc.) over filter
strip (D),
4. Using wrench, tighten three screws (C).
TA250648
Go on to Sheet 2