TM 9-2350-222-20-1-4
REPLACEMENT OF HULL INTERMEDIATE LEAD ASSEMBLY {Sheet 3 of 4)
INSTALLATION:
Connect connector (A) of replacement hull intermediate lead assembly (B) to short lead
1.
(C) of dust detector warning light harness assembly.
Route replacement hull intermediate lead
2.
assembly (B) beneath cable retaining
straps from dust detector warning light
box (D) to starter cable bulkhead connec-
tor.
Insert lead assembly (B) through retaining nut (E) and bushing (F).
3.
Install pin (G) into position "C" of insert (H).
4.
5.
Slide bushing (F) against insert (H).
6. Slide sleeving against bushing (F).
7. Install retaining nut (E) on shell (K).
TA250642
Go on to Sheet 4
10-350.11
Change 3