TM 9-2350-222-20-1-4
DOMELIGHT ASSEMBLY REPAIR (Sheet 1 of 8)
PROCEDURE INDEX
PROCEDURE
PAGE
Disassembly
Cleaning and Inspection
Assembly
TOOLS: Flat-tip screwdriver
Cross-tip screwdriver
8 in. adjustable wrench (crescent)
Long round nose pliers (needle nose)
PRELIMINARY PROCEDURE:
DISASSEMBLY:
1.
Using flat-tip screwdriver, unscrew eight
captive screws (A).
2.
Separate door assembly (B) from body assembly
(c).
3.
Using flat-tip screwdriver, remove electrical
lead (E) from rotary switch (F).
4.
Using needle nose pliers, remove eight rings (D)
from captive screws (A). Remove captive screws
(A).
GO on to Sheet 2
TA139770
10-215