TM 9-2350-222-20-1-4
HYDRAULIC PUMP SWITCH REPLACEMENT (Sheet 1 of 1)
TOOLS: Flat-tip screwdriver
REMOVAL:
1.
Disconnect connector (A) from switch (B).
2.
Using screwdriver, remove two screws (C).
3.
Remove switch (B) from bracket (D).
INSTALLATION:
1.
Position switch (B) in bracket (D) and start two
screws (C),
2.
Using screwdriver, tighten two screws (C).
3.
Install connector (A) on switch (B).
End of Task
TA139715
10-159