TM 5-5420-226-20-1
Symptom-39
DETAILED
TROUBLESHOOTING
PROCEDURE
INDICATOR
- GAGE
FROM
STEP
1
(Continued)
o2
I
Check
FUEL TANKS
selector
switch for continuity
through
circuit that indicated
wrong (CKT 30 for left
fuel tank, CKT 31 for right fuel tank).
First
Technician
(Operators
StatIon)
l Set MASTER
BATTERY
switch
OFF.
l Displace gage instrument
panel (page
10-111 ).
l Disconnect
fuel tanks
selector
switch
cable
(CKT
28)
from
FUEL
TANKS
selector
switch.
l Set FUEL TANKS
selector
switch
to circuit
being
checked
(L for CKT
30, R for CKT
3
1).
l Disconnect
gage instrument
panel harness
connector
of
CKT
30 or CKT
31 (as indicated
by fault
in
Step
@
from
FUEL
TANKS
selector
switch.
l Set multimeter
to OHMS
X 1 scale and zero
meter, or
use STE/ICE
Test
No. 91 (page
4-83).
l Connect
red probe
of meter
to gage instrument
panel
harness
connector
of circuit
disconnected
in above step.
l Connect
black
probe
of meter
~o center
connector
of
FUEL
TANKS
selector
switch.
l Check if meter indicates
continuity.
Does
meter
indicate
continuity?
I
CKT
R FUEL
31
. TANK
\
n+
o I
-
T 28
I
,.&2K
(
)
Replace
FUEL TANKS
selector
switch
(page
10-1
32).
TA107168
4-479