TM 5-5420-226-20-1
(
Symptom-33
DETAILED
TROUBLESHOOTING
PROCEDURE
INDICATOR
- GAGE
FOR
CLARITY
QUADRANT
(Continued)
ASSEMBLIES
NOT
SHOWN
~Check
front accessory
harness
(CKT 33) at bulkhead
~
disconnect
for short
to ground.
ISecondTechnician(CommandersStation)
l
l
l
l
Install
basket-indicator
panel
harness
(CKT
33) at
basket
disconnect.
Displace
front
accessory
harness
connector
at
bulkhead
disconnects
(page
10-269).
Connect
red probe of meter
to contact
H (CKT
33) of
front
accessory
harness
connector
at bulkhead
disconnect
and black
probe
to ground.
Check
if meter
indicates
continuity.
9
floes
meter
indicate
continuity,
thereby
indicating
a
~ short?
l Inspect front accessory
harness
for bent/broken
connector
contacts
or loose
CKT 33 wire at rear of
connectors.
l Repair connectors
if
defective
(page
10-298).
l If connectors
are not
defective,
notify
support
maintenance
of a defective
front accessory
harness.
l Install front accessory
harness
connector
at
bulkhead
disconnect
(page
10-270).
l Connect
gage
instrument
panel
harness
connector
to
ENGINE
TEMP
indicator
gage.
l Install gage instrument
panel
(page
10-112).
-0YES
?
CONTACT
H
(CKT
13)
TA107121
4-432