TM 5-5420-226-20-1
(
(
Symptom-33
DETAILED
TROUBLESHOOTING
PROCEDURE
INDICATOR
- GAGE
(Continued)
Check
basket-indicator
panel
harness
at basket
~
disconnect
forshort
to ground.
First
Technician
(Operators
Station)
l Connect
basket-instrument
panel
harness
connector
to gage indicator
panel.
Second
Technician
(Commanders
Station)
l Displace basket-indicator
panel
harness
connector
(CKT
33) at basket
disconnect.
l Connect red probe of meter to contact G (CKT 33) of
basket-indicator
panel
harness
connector
and black
probe
to ground.
l Check if meter indicates continuity.
9
Does meter
indicate
continuity,
thereby
indicating
a
~ short?
Inspect
basket-indicator
panel
harness
for bent/broken
connector
contacts
or loose
CKT 33 wire at rear of
connectors.
Repair connectors
if defective
(page
10-298).
If connectors
are not
defective,
notify
support
.
maintenance
of a defective
basket
to indicator
panel
harness.
Connect
gage
Instrument
panel
harness
connector
to
ENGINE
TEMP
indicator
gage.
Install
gage
instrument
panel
(page
10-112).
QYES
FOR
CLARITY
QUADRANT
ASSEMBLIES
NOT
SHOWN
---
4-431
.