TM 5-5420-226-20-1
DETAiLED
TROUBLESHOOTING
PROCEDURE
Symptom-32
INDICATOR
- GAGE
(Continued)
accessory
harness
(CKT 36) from
connector
at basket
disconnect
to connector
at bulkhead
disconnect
for continuity.
Second Technician
(Commanders
Station)
Displace front accessory harness connector (CKT 36) at
buikhead disconnect
(page 10-269).
Connect black probe of meter to contact C (CKT 36) of
front accessory harness connector at basket disconnect.
Connect red probe of meter to contact F (CKT 36) of
front accessory harness connector
at bulkhead
disconnect.
l
Check if meter indicates continuity.
Does meter indicate
continuity?
l
l
l
l
l
l
inspect
front
accessory
harness
for bentlbroken
connector
contacts
or loose
CKT 36 wire at rear of
connectors.
Repair connectors
if defective
(page 10-298).
If connectors
are not
defective,
notify
support
maintenance
of a defective
front
accessory
harness.
Install front
accessory
harness
connector
at
bulkhead
disconnect
(page 10-270).
Instail
basket-indicator
panel
harness
connector
at basket
disconnect.
install
gage instrument
panei
(page 10-112).
ii
I
II ,
I
,1
L,
@l
@f
y:
T
..
,.
---
. .
(CKT 36)
BULKHEAD
DISCONNECTS
FOR CLARITY
QUADRANT
ASSEMBLIES
NOT SHOWN
I
CKT
I
BASKET
BULKHEAD
DISCONNECT
CONTACT
l
TA1071O7
~
4-418