TM 5-5420-226-20-1
Symptom-28
DETAILED
TROUBLESHOOTING
PROCEDURE
T
VEHICLE
OPERATION
- HULL POWER
(Continued)
.
Check CKT 459 in control panel power harness for
continuity.
Second Technician
(Operators
Station)
l Set MASTER BATTERY switch OFF.
l Disconnect basket-control panel power harness
connector
from master control panel.
l Connect red probe of meter to contact D (CKT 459) of
control panel power harness panel connector.
l Connect black probe of meter to control panel power
harness connector
at MASTER
BATTERY
switch
(CKT 459).
l Check if meter indicates continuity.
Does meter indicate continuity?
n
ci.!%!
9
.-
2
I
(
MASTER
CONTROL
PANEL
(REAR
VIEW)
l Repiace controi panei power
harness
(page 10-101).
l Connect control panel
starting
harness
connector
to MASTER BA7TERY switch.,
l Connect three battery
ground
straps
(page 10-268).
I
TA107O73
4-384