TM
5-5420-226-20-1
Symptom-5
DETAILED
TROUBLESHOOTING
PROCEDURE
VEHICLE
OPERATION
- POWERPLANT,
STARTING
(Continued)
~Check
for continuity
from adaptor
assembly
to fuel
[
pump connector.
Second
Technician
(Rear
Underside
of Hull)
l Isolate and drain left fuel tank (page 7-191).
r.-
--CAUTION.----
I Removedebris,
if any, to prevent
it
I
l I
from entering
fuel tank which could
I
I
clog pump and fuel lines.
I
I
I
I
I
L ----
-----
---
r
J
m
First
Technician
(Engine
Compartment)
l Remove fuel pump access cover (page 7-11).
l Disconnect
electrical
cable from
fuel pump.
l Connect
red probe
of meter
to cable connector
(CKT
76),
l Connect
black
probe
of meter
to cable and adapter
assembly
connector
(CKT
76),
l Check if meter indicates
continuity.
Does meter
indicate
continuity?
LEFT FUEL TANK
FUEL PUMP
k%
-
l\~
A,.-,-
Replace
cable and adapter
assembly
(page
10-321).
II
[
CABLE
AND
ADAPTOR
ASSEMBLY
FUEL PUMP
/%)
ACCESS
COVER
=.
}#-
I
76
LEFT FUEL TANK
TA106869
4-180