TM
5-5420-226-20-1
Symptom-5
DETAILED
TROUBLESHOOTING
PROCEDURE
VEHICLE
OPERATION
- POWERPLANT,
STARTING
(Continued)
m
Check capacitor
lead for internal
short.
?
First
Technician
(Engine
Compartment)
l Connect red probe of meter to outside of capacitor
and
housing
assembly.
,
l Connect black probe of meter to capacitor
and housing
assembly
connector
contact
(CKT
76).
l Check if multimeter
indicates
continuity.
Does multimeter
indicate
continuity?
H
(
AND
ADAPTER
ASSEMBLY
Repair capacitor and housing
assembly (page 10-326).
I
TA106868
4-179