TM
5-5420-226-20-1
.-
Symptom-5
DETAILED
TROUBLESHOOTING
PROCEDURE
VEHICLE
OPERATION
- POWERPLANT,
STARTING
(Continued)
~
WARNING
Do not
smoke
or allow
flames
or
sparks
within
area
while
draining
tanks. Have manned fire extinguisher
present.
Check for continuity
from adaptor
assembly
to fuel
pump connector.
Second
Technician
(Rear
Under
Side of Hull)
l Isolate and drain right fuel tank (page 7-194).
First
Technician
(Rear
of Crew
Compartment)
l Remove right rear access plate (page 17-7).
l Remove right fuel pump access cover (page 7-5).
l Disconnect
electrical
cable
from
fuel pump.
l Connect
black
probe
of meter
to cable
connector
(CKT
76).
l Connect
red probe
of meter
to cable
and adapter
assembly
(CKT
76).
l Check if meter indicates
continuity.
f
Does meter
indicate
continuity?
9
/
L___
~1
I
ADAPTER
ASSEMBLY
CONNECTOR
\
(CKT 76)
RIGHT
REAR
1/
ACCESS
DOOR
assembly (page 10-326).
I
VIEW WITH
CAPACITOR
AND
HOUSING
ASSEMBLY
REMOVED
TA106862
4-173