TM
5-5420-226-20-
I
Symptom-5
T
DETAILED
TROUBLESHOOTING
PROCEDURE
VEHICLE
OPERATION
- POWERPLANT,
STARTING
(Continued)
)
1
Check
capacitor
lead for internal
short.
First
Technician
(Rear
of Crew
Compartment)
l Connect
red probe
of meter
to capacitor
and housing
assembly
connector
contact
(CKT
76).
l Connect black probe of meter to outside of the capacitor
and housing
assembly.
l Check if meter indicates
continuity.
Does meter
indicate
continuity?
q
(
o
)
Repair
capacitor
and housing
assembly
(page
10-326).
TA106861
4-172