TM 5-5420-226-20-1
Symptom-2
DETAILED
TROUBLESHOOTING
PROCEDURE
T
VEHICLE
OPERATION
- POWERPLANT,
STARTING
(Continued)
-.
#Check
fire extinguisher
fuei shutoff
switch
for
continuity
(internal
short).
First
Technician
(Commanders
Station)
l Install front accessory
harness
connector
at
buikhead
disconnect
(page
10-270).
#
l Install engine upper access panei (page 17-15).
Second
Technician
(Operators
Station)
l
l
l
l
Disconnect
front
accessory
harness
connectors
(CKT
975) from
fire extinguisher
fuel shutoff
switch.
Set multimeter
to OHMS
Xl
scale andzero
meter,
or use STE/ICE
Test
No. 91 (page 4-83).
Connect
oneprobe
of meter
to each disconnected
fuel shutoff
switch
connector.
Check
if meter
indicates
continuity.
Didmeter
indicate
continuity,
thereby
indicatinga
I
shorted
switch?
l Repiace
fire extinguisher
and
Ifuei shutoffrelay
(page
10-141).
Il Connectfront accessory
harness
connectors
to fire
extinguisher
fuel shutoff
~
switch.
1Replacefuei shutoffswitch
(page 20-29).
oNO
F
TA106836
...
4-147