TM
5-5420-226-20-1
SvmrMom-1
DETAILED
TROUBLESHOOTING
PROCEDURE
.
.
VEHICLE
OPERATION
- POWERPLANT,
STARTING
T
(Continued)
)
1
Check
neutral
shift switch
for continuity.
First
Technician
(Operators
Station)
l
Set MASTER
BATTERY
switch
OFF.
Second
Technician
(Rear
Grille
Doors)
l
Set multimeter
to OHMS X 1 scale and zero meter, or
use STE\ICE
Test No. 91 (page 4-83).
l
Connect red probe of meter to one of the neutral
shift
switch
connectors.
l
Connect
black
probe
to the other
neutral
shift
switch
connector.
First Technician
(Operators
Station)
l
Move shift lever from L to N several times,
Second
Technician
(Rear
Grille
Doors)
l
Check
if meter
indicates
continuity
each time the shift
lever is moved
to N.
Does meter indicate
continuity
each time the shift le-
ver is moved
to N.
n
o
NEUTRAL
SWITCH
CONNECTORS
(CKT 14)
l
Adjust
neutral
shift
switch
(page 11-81).
l
If switch cannot be adjusted,
replace
neutral
shift
switch
(page 10-236).
TA106785