TM 5-5420-226-20-1
Symptom-1
DETAILED
TROUBLESHOOTING
PROCEDURE
VEHICLE
OPERATION
- POWERPLANT,
STARTING
(Continued)
l If STE/lCE
is available,
perform
(page 4-70).
I Step@.
l If STE/lCE is not available, go to
I
Check
for sound
of starter
solenoid
and/or
starter
engaging.
Second
Technician
(Top
Deck)
l Open right top deck grille doors.
l
Listen
for clicks
or other
noise
coming
from
starter
when starter
switch
is pressed.
First
TechnicIan
(Operators
Station)
l
Set FUEL PUMPS switch OFF.
l
Press STARTER
switch
several
times,
Is.there
a clicking sound, or other noise from starter
when STARTER
switch is pressed?
1
RIGHT TOP
DECK GRILLE
DOORS
l
Check for locked
engine.
.
See Step
@
.
/
TA106782