TM 5-5420-226-20-1
P r e v e n t i v e M a i n t e n a n c e C h e c k s a n d S e r v i c e s f o r M 4 8 A 5 A V L B H u l l -
C o n t i n u ed
Item
No.
32
Interval
Semiannual
Location
Item to
Check/Service
Dust Detector
Filter Strip (Left
and Right Sides)
(If Equipped)
Procedure
Not Fully Mission
Capable if:
NOTE
Service dust detector filter strip quarterly, or after 750 miles of
operation, or when dust detector indicates ingestion of foreign matter.
Open top deck grille doors
(TM 5-5420-202-10).
Remove dust and dirt from filter
strip cover and compressor housing.
Loosen three screws securing filter
strip cover to compressor housing.
Remove cover.
Remove filter strip with retainer
from filter strip cover
(page 7-116.11).
Clean cover and mounting face of
compressor housing.
Inspect compressor housing chamber
for contamination. Clean chamber as
required.
3-40
Change 6