TM 9-2350-222-20-1-4
BILGE PUMP STOWAGE RECEPTACLE PLATE REPLACEMENT (Sheet 1 of 2)
7/16 in. socket with 1/2 in. drive
7/16 in. combination box and open end wrench
11/32 in. open end wrench
Flat-tip screwdriver
6 in. extension with 1/2 in. drive
SUPPLIES: Lockwashers (MS35330-40) (4 required)
Lockwashers (MS35338-40) (2 required)
1. Using 7/16 inch wrench to hold nut (A), use
socket to remove screw (B), lockwasher (C),
ground strap from fuel pump (D), washer (E),
clamp (F), and lockwasher (G). Throw
2. Remove plate (H) from plate assembly (J).
3
Remove connector (K) from shell (L).
4. Using screwdriver, remove four screws (M) and
5. Remkove shell (L) from plate (H).
Go on to Sheet 2
10-150