TM 9-2350-222-20-1-4
MASTER CONTROL PANEL REPAIR (Sheet 24 of 65)
Gas Particulate Switch and Indicator Light Replacement (Sheet 3 of 4)
INSTALLATION:
Apply silicone compound (Item 32, Appendix D) to electrical connector on base assembly (A).
1.
2.
Using fingers, connect electrical connector (circuit 415) to rear of base assembly (A) by pushing in.
Place base assembly (A) in position on panel.
3.
4.
Using screwdriver, install two screws (B) and new lockwashers (C) securing base assembly (A) to
panel.
Using fingers, install lamp (D) by pushing in and turning clockwise.
5.
Install new preformed packing (F) on adapter (G).
6.
7.
Using fingers, install adapter (F) and lens (G) in panel.
Go on to Sheet 4
TA139634
10-78