TM 9-2350-222-20-1-4
MASTER CONTROL PANEL REPAIR (Sheet 25 of 65)
Gas Particulate Switch and Indicator Light Replacement (Sheet 4 of 4)
Apply silicone compound (Item 32, Appendix D) to two male connectors for switch (H).
8.
Using fingers, connect two electrical connectors to switch (H) by pushing in.
9.
NOTE
Before installing switch (H), make sure switch (H) is in OFF
position. If off position is not marked on switch (H), use
multimeter to make sure switch (H) is on OFF position.
10. Place switch (H) in position on panel.
11. Using screwdriver, install two screws (J) and new lockwashers (K) securing switch (H) to panel.
End of Task
TA139635
10-79