13. Using 1/4 inch screwdriver, install screw (P) and new
lockwasher (Q) to secure capacitor ground strap (R)
to armature end of motor (C).
14. Slide insulator (S) over end capacitor lead (T) and
connect lead (T) to lead (U) at end of motor as
shown, then slide insulator (S) over connectors.
15. Install new packing (V) in groove in housing (L).
16. Position cover (W) to housing (L).
17. Install 10 screws (X) and 10 new lockwashers (Y) to
secure cover (W) to housing (L).
19. Place both electrical leads (Z) in position and secure
18. Using 1/4 inch screwdriver, tighten 10 screws (X).
with retaining strap (AA). Using 1/4 inch screwdriver,
secure retaining strap (AA) to housing (L) with new
lockwasher (AB) and screw (AC).
End of Task
TA252583
Change 1 4-12