TM 9-2350-222-20-2-3-2
CUPOLA COVER REMOVAL PROCEDURE
36-3.
9/16 in. socket (3/8 in. drive)
TOOLS:
Flat-tip screwdriver
PERSONNEL: One
TM 9-2350-222-10 for procedures to:
REFERENCES:
Elevate and depress caliber .50 machine gun
Open and close M36/M36E1 periscope ballistic shield
EQUIPMENT LOCATION INFORMATION:
CALLOUT
FOLDOUT
EQUIPMENT
11
Driver's Master Control Panel
Driver's master control panel MASTER BATTERY switch set to OFF
EQUIPMENT CONDITION:
FRAME 1
PROCEDURE
STEP
1.
Open M36/M36E1 periscope ballistic shield (TM-10).
2.
Using screwdriver, remove clamp (1) from gun mount (2).
3.
Fully elevate gun (TM-10).
4.
Using socket wrench, remove eight locknuts (3) and eight flat washers (4) from studs (5).
Depress gun to horizontal position (TM-10).
5.
Remove five straps (6) from cover (7).
6.
Remove cover (7) from studs (5).
7.
8.
Close M36/M36E1 periscope ballistic shield (TM-10).
END OF TASK
Para 36-3
36-2 Change 1