32-19. SAFETY RELAY REMOVAL PROCEDURE (CONT)
FRAME 1
Procedure
1.
Using adjustable wrench, disconnect electrical connector (1) from safety relay (2)
(JPG).
Using 7/16" combination wrench, remove two screws (3) two Iockwashers (4) that
2.
attaches ground lead (5) and safety relay (2) to bracket (6). Remove safety relay.
END OF TASK
Para 32-19 Cont
32-44