TM 9-2350-222-20-2-3-2
BREECHRING FIRING CONTACTS INSTALLATION PROCEDURE
32-8.
TOOLS: 5/16" socket head screw key (Allen wrench)
Flat tip screwdriver
PERSONNEL: One
EQUIPMENT LOCATION INFORMATION:
EQUIPMENT
CALLOUT
FOLDOUT
Driver's Master Control Panel
11
Gunner's Control Box
2
Loader's Safety Switch
24
EQUIPMENT CONDITION: MAIN GUN switch on gunner's control box set to OFF
Loader's safety switch set to SAFE
Driver's master control panel MASTER BATTERY switch set to OFF
Para 32-8
32-20