TM 9-2350-222 -20-2-3-2
H I N G E D PLATE INSTALLATION PROCEDURE (CONT)
19-9.
FRAME 1
Procedure
Step
Traverse turret until periscope stowage box (1) can be reached from driver's compartment
1.
(TM-10).
Set turret traverse lock to LOCKED (TM-10).
2.
Open two latches (2) and open door (3).
3.
Open door (4) to get to inside of periscope stowage box (1).
4.
Open two latches (5) and open door (6).
5.
NOTE
Check near location of hinged plate (7) on periscope
s t o w a g e box (1) and door (4) for number of flat
washers (8) that was written down during hinged plate
removal ( para 19-8 ). Note that flat washers ( 8 ) go
under hinged plate and Iockwashers (9) go under nuts
(10). Check hinged plate (7) for pencil mark made
during hinged plate removal ( para 19-8 ). Use this mark
to find top of hinged plate so it can be put back in place.
Using screwdriver and wrench, attach hinged plate (7) to periscope stowage box (1) with
6.
two screws (11), two Iockwashers (9), two nuts (10) and same number of flat washers
(8) as removed.
7.
Close door (6).
Using screwdriver and wrench, attach hinged plate (7) to door (4) with two screws (11),
8.
two lockwashers (9), two nuts (10) and same number of flat washers (8) as removed.
9.
Close doors (4) and (3).
END OF TASK
Para 19-9 Cont
19-20