TM 9-2350-222-20-2-1
SYNCHRONIZATION AND BACKLASH CHECK OF 165 MM GUN WITH
3-4.
GUNNER'S PERISCOPE M32C-RAMP METHOD (CONT)
FRAME 14
Procedure
Step
Return periscope boresight knobs to zero. Return periscope slip scales to normal settings
1.
(TM-10).
2.
Remove breech boresight 8769218 from breech chamber (TM-10).
3.
Have driver return tank to level ground.
4.
Remove boresight threads from gun muzzle.
END OF TASK
Para 3-4 Cont