TM 5-5420-226-20-1
(
Symptom-55
DETAILED
TROUBLESHOOTING
PROCEDURE
SUPPORT
SYSTEM
- GAS PARTICULATE
{Continued)
~
WARNING
Unit commander
or senior
officer
in
charge of maintenance
personnel
as-
signed
to
remove
and
dispose
of
contaminated
gas
filters
must
prescribe
necessary
clothing
(TM 10-
277) to be worn during this operation.
He must
also
prescribe
necessary
safety measures
that must be follow-
ed including
decontamination
oper-
ation that must be performed
before
new
gas
filters
are
installed
(TM3-
220).
~ Check for restricted
airflow
at gas particulate
filter air
outlet.
Second
Technician
(Operators
Station)
l Set GAS PARTICULATE
switch
OFF.
First
Technician
(Commanders
Station)
l Disconnect faulty air hose from gas particulate
precleaned.
Second
Technician
(Operators
Station)
l Set GAS PARTICULATE
switch
ON.
First
Technician
(Commanders
Station)
l Hold hand over filter unit outlet to air hose and check
for free airflow.
Second
Technician
(Operators
Station)
l Set MASTER
BATTERY
switch
OFF.
l Set GAS PARTICLTLATE
switch
OFF.
Is there free airflow
from filter unit?
Servicegas particulatefilter unit.
OUTLET
HOSES
PRECLEANED
AND PARTICULATE
FILTER
UNIT
l Remove
blockage
from faulty
air hose.
l If
blockage
cannot
be
removed
repiace
faulty
air
hose.
/
v
TA107269