TM 5-5420-226-20-1
DETAILED TROUBLESHOOTING
PROCEDURE
Symptom-54
SUPPORT
SYSTEM
- FIRE EXTINGUISHER
(Continued)
STEPo1CONTINUED
T
FIRE EXTINGUISHER
RELAY
First
l
l
Technician
(Commanders
Station)
Remove
right-hand
floor access cover (page 17-9).
Listen for click sound from fire extinguisher
relay when
FIRE-PULL
HARD
interior
control
handle
is pulled
and another
click
10 seconds
later.
Second
Technician
(Operators
Station)
l Pull FIRE-PULL
HARD
interior
control
handle
and
release
it.
4
Did relay close and stay closed for a minimum
of 10
seconds?
I
FOR CLARITY
QUADRANT
=
ASSEMBLIES
NOT SHOWN
(.Check front accessory
harness
(CKT 975A, 54A) for
continuity
from bulkhead
connector
to connector
at fire
extinguisher
relay.
.
See Step
@
.1
, TA107258
4-569