TM
5-5420-226-20-1
Symptom-53
DETAILED
TROUBLESHOOTING
PROCEDURE
SUPPORT
SYSTEM
- FIRE EXTINGUISHERS
(Continued)
r
.- L --CAUTION.
----
1
I Donotengage control valve mount- I
I
ingnutto
cylinder while doing this
I
I
check.
L . .
r
-----
-0---
~
z Check operation of first shot control valve when
I
exterior
first shot handle
is pulled.
I
First
Technician
(Front
of Crew
Compartment)
l Return
first
shot
control
valve to set position.
.
Hold
control
valve away
from
and above
first shot
cylinder.
Second
Technician
(Front
of Vehicle)
l Pull first shot exterior
handle.
First
Technician
(Front
of Crew
Compartment)
l Check if pin in control
valve did extend.
Did pin in control
valve extend?
l Repair first shot control
valve
(page 20-51).
l Installsafety wire and lead
.
seals on first shot exterior
handle.
)l Replacefire extinguisher
cylinder (page 20-53).
l Installsafety wire and lead
seal on first shot exterior
handle.
l Install safety wire and.lead
seals on first shot control
valve.
oNO
oYES
u
PINZ
CONTROL
VALVE
SAFETY
PIN
REMOVED
FOR
CLARITY
I
HANDLE
TA107252
4-563