TM
5-5420-226-20-1
--
DETAILED
TROUBLESHOOTING
PROCEDURE
Symptom-3
VEHICLE
OPERATION
- POWERPLANT,
STARTING
ENGINE
CRANKS
SLOWLY
AND WILL
NOT START.
~
NOTE
This procedure
is to be performed
by
two
persons.
The
lead
person
is
referred
to as the first technician
and
shall direct the activity
of the second
person called the second
technician.
m
# Check
BAIT
GEN INDICATOR
gage for above
mid
yellow
indication.
I
Second
Technician
(Operators
Station)
l Set MASTER
BATTERY
switch
ON.
l Visually check if BATT GEN INDICATOR
gage
indicates
above
mid yellow,
l Set MASTER
BATTERY
switch
OFF.
Does BAIT
GEN INDICATOR
gage indicate
above
mid yellow?
(
Service
batteries
(TM 5-5420-226-10).
Charge
batteries
(TM 9-6140-200-14).
If STE/lCE
is available,
perform
Test No. 77/79:
BAITERY
CONDITION
TEST
(page
4-60).
TA106842