TM 5-5420-226-20-1
Item
No.
38
P r e v e n t i v e
Interval
Semiannual
M a i n t e n a n ce C h e c k s a n d S e r v i c e s f o r M 4 8 A 5 A V L B H u l l -
Location
Item to
Check/Service
Final Drive
Universal Joints
and Disconnect
Flanges (Left and
Right Side)
C o n t i n u e d
Procedure
Check universal joint and disconnect
flanges for cracks and damage.
Check for missing or broken
lockwire.
If lockwire is missing or broken,
check that screws are tightened to
at least 118 lb-ft (160 Nm). It may
be necessary to remove power plant
(page 5-2) before torque can be
checked. Do not tighten loose screws,
replace them. Tighten new screws to
118-128 lb-ft (160-173 Nm).
Not Fully Mission
Capable if:
Change 6 3-53