TM 9-2350-222-20-1-4
POWER PLANT WARNING LIGHT REPAIR (Sheet 2 of 2)
CLEANING AND INSPECTION:
1.
Clean lens (A) with moist, lint-free cloth (Item 12, Appendix D).
2.
Using steel wool (Item 55, Appendix D), remove any corrosion from connector terminal (K) of lamp
assembly (G).
3.
Inspect lens for cracks or deep scratches. Replace if any are found.
INSTALLATION:
NOTE
Apply silicone compound (Item 32, Appendix D) to mating
surfaces of light assembly (G) and connector (H).
1.
Using fingers, connect electrical connector (H) to light assembly (G).
2.
Using screwdriver, secure light assembly (G) to bracket (J) with two screws (E) and new
Insert lamp (D) in socket. Press in and turn slightly right, and release to secure.
3.
4.
Using wrench, install adapter (C).
Place new packing (B) on adapter (C) and install lens (A) finger tight.
5.
Place MASTER BATTERY switch to ON and check that lamp (D) lights,
6.
End of Task
TA139764
10-209