TM 9-2350-222-34-1
SERVICE UPON RECEIPT - Continued
4. Corrective action for items listed in paragraph 3 found deficient will be corrected as follows:
a. Water in fender stowage boxes should be drained by removing 1/4 inch headless drain plugs (two in each
box) as required to allow water to drain. After water has drained, reinstall and tighten plugs.
b. Protective barrier plugs should be reinstalled and tightened after water has drained.
c. Connect tubes to turbosupercharger. Refer to TM 9-2350-222-20-1.
TA130432
2-6