TM 9-2350-222-20-2-3-2
36-21.
CUPOLA POWER SWITCH REMOVAL PROCEDURE (CONT)
PROCEDURE
Using pencil and masking tape, mark top of switch (1) so that switch is put in proper position during
1.
installation.
Using screwdriver, remove two screws (2) and two lockwashers (3).
2.
3.
Remove switch (1) from panel (4).
4.
Disconnect electrical connector (5) of circuit 111C from switch terminal 2 (JPG).
5.
Disconnect electrical connector (6) of circuit 111B from switch terminal 3 (JPG).
Disconnect electrical connector (7) of circuit 111 from switch terminal 1 (JPG).
6.
END OF TASK
Para 36-21 Cont
Change 1 36-55