TM 9-2350-222-20-2-3-2
36-19.2 RESISTOR (LATE MODEL) INSTALLATION PROCEDURE (CONT)
PROCEDURE
1.
Put lockwasher (1), spacer (2), resistor (3), spacer (4) and flatwasher (5) on screw (6),
2.
Using screwdriver, install screw (6) in panel (7).
3.
Install screw (8), lockwasher (9), flat washer (11), to secure one end of strap (11), grenade power box
ground lead (12), and resistor ground lead (13). And star lockwasher (14).
4.
Use 7/16 inch wrench to tighten screw (8).
Connect electrical connector (15) to wiring harness lead (16) (JPG).
5.
END OF TASK
Para 36-19.2 Cont
Change 1 36-54.3