TM 9-2350-222-20-2-3-2
36-4.
CUPOLA COVER INSTALLATION PROCEDURE
9/16 in. socket (3/8 in. drive)
TOOLS:
Flat-tip screwdriver
Self-locking nuts (MS21083-N6) (8 req'd)
SUPPLIES:
PERSONNEL One
REFERENCES:
TM 9-2350-222-10 for procedures to:
Elevate and depress caliber .50 machine gun
Open and close M36/M36E1 periscope ballistic shield
EQUIPMENT LOCATION INFORMATION:
FOLDOUT
CALLOUT
EQUIPMENT
11
Driver's Master Control Panel
Driver's master control panel MASTER BATTERY switch set to OFF
EQUIPMENT CONDITION:
PROCEDURE
1.
Open M36/M36E1 periscope ballistic shield (TM-10).
Put cover (1) over eight studs (2).
2.
Put five straps (3) in correct position over studs (2).
3.
4.
Elevate gun to maximum (TM-10).
5.
Using socket wrench, put on eight flat washers (4) and eight new locknuts (5). Tighten eight locknuts.
6.
Using screwdriver, put clamp (6) around gun mount (7). Tighten clamp.
7.
Close M36/M36E1 periscope ballistic shield (TM-10).
END OF TASK
Para 36-4
36-4 Change 1