TM
9-2350-222-20-2-3-2
OPERATING CRANK FIRING CONTACT REMOVAL PROCEDURE (CONT)
32-9.
Step
Procedure
1.
Using Allen wrench, remove three screws (1) that attach cover (2) to crank (3).
Remove cover (2), insulator (4), male contact (5), spring (6), female contact (7), and
2.
insulator (8) from crank (3).
END OF TASK
Para 32-9 Cont
32-25