TM 9-2350-222-20-2-3-2
BOTTOM FRONT DOOR I N S T A L L A T I O N PROCEDURE
19-7.
TOOLS: Cross tip screwdriver ( Phillips)
3/8 open end wrench
SUPPLIES: Screws. MS35207-264 (seven)
Nuts. MS21044-N3 (seven)
PERSONNEL: One
REFERENCES: TM 9-2350-222-10 for procedures to:
Traverse turret
Set turret traverse lock to LOCKED
EQUIPMENT LOCATION INFORMATION:
FOLDOUT
CALLOUT
EQUIPMENT
11
Driver's Master Control Panel
7
Turret Traverse Lock
9
Periscope Stowage Box
EQUIPMENT CONDITION: Driver's master control panel MASTER BATTERY switch set to OFF
FRAME 1
I
Procedure
Step
Traverse turret until periscope stowage box (1) can be reached from driver's compartment
1.
(TM-IO).
2.
Set turret traverse lock to LOCKED (TM-10).
and hold in
Place front side of door (2) against hinge (3) of periscope stowage box (1)
3.
open position.
NOTE
Put in screws (4) with, screw head inside periscope
stowage box (1).
Using screwdriver and wrench, attach door (2) to hinge (3) of periscope stowage box (1)
4.
with six screws (4) and six nuts (5).
Close door (2) of periscope stowage box (1).
5.
END OF TASK
Para 19.7
19-12