TM 9-2350-222-20-2-1
SYNCHRONIZATION AND BACKLASH CHECK OF 165 MM GUN WITH
3-4.
GUNNER'S PERISCOPE M32C-RAMP METHOD (CONT)
FRAME 8
Procedure
Step
Check boresight knob readings taken at the different gun positions. If deflection readings
1.
exceed 0.3 mil return to level ground and repeat frames 1 through 7 and this step.
If deflection reading on gunner's periscope deflection slip scale (1) still exceeds 0.3 mil
2.
replace gunner's periscope head (TM-10) and repeat frames 1 through 7 and step 1
above. If deflection error still exceeds 0.3 mil notify support maintenance. If deflection
error was within 0.3 mil continue to step 3.
If elevation reading on gunner's periscope elevation slip scale (2) exceeds 0.3 mil
3.
continue to step 4. If elevation error was within 0.3 mil go to frame 9.
Adjust eccentrics on 11 inch arm (para 3-7) until aiming cross of gunner's periscope
4.
daylight reticle is on same aiming point as gun (view A).
GO TO FRAME 9
Para 3-4 Cont
3-19