TM 9-2350-222-20-2-1
TURRET AND WINCH ANNUAL PREVENTIVE MAINTENANCE (CONT)
2-8.
FRAME 2
Item to be Inspected
Step
Procedure
Reference
Before relieving pressure in equilibrator make sure that
gun is at its maximum elevation.
Equilibrator Reservoir
1.
a.
Reduce equilibrator pressure
Drain
by opening valve.
Remove reservoir.
b.
TM 20-2-3
(para 47-4)
Remove hand pump
c.
TM 20-2-3
assembly.
(para 47-2)
TM 20-2-3
Drain hydraulic fluid into a
d.
(para 1-27)
container.
Check hydraulic oil for
TM 20-2-3
e.
bubbles. If a large
(para 44-2, 44-3)
amount of bubbles are
TM 20-2-3
(para 47-6, 47-7)
present, remove main
accumulator for servicing
TM 20-2-3
by support maintenance.
(para 47-3, 47-5)
TM 9-2350-22-10
Change filter.
f.
Install hand pump
g.
assembly and reservoir.
Fill reservoir with
h.
hydraulic fluid.
When proper pressure is
i.
indicated balance
equilibrator.
END OF TASK
Para 2-8 Cont
2-20