TM 9-2350-222-20-2-1
SEMIANNUAL (180 DAY) PREVENTIVE MAINTENANCE (CONT)
2-2.
a.
Turret (Cont)
FRAME 2
Step
Procedure
Reference
Item to be Inspected
1.
Main Accumulator
Check main accumulator for
TM 20-2-3
(para 1-18, 1-19)
Recharge pressure using
LO 9-2350-222-12
accumulator charging device or
reduce pressure as required.
Add oil if necessary.
Check manual elevation
2.
Manual Elevation
TM 20-2-3
accumulator for proper
Accumulator
(para 1-20)
LO 9-2350-222-12
pressure using accumulator
charging device or reduce
pressure as required. Add oil
if necessary.
GO TO FRAME 3