TM 9-2350-222-20-1-5
SMOKE GENERATOR SOLENOID REPLACEMENT (Sheet 5 of 5)
Position assembled solenoids (B) and bracket (E)
10.
to engine.
Using 3/4 inch socket, install and tighten two
screws (J) to secure bracket (E) to engine.
13.
Connect elbow-to-solenoid hose (L) to 90-degree
elbow (C).
14.
Connect output fuel hose (M) to 45-degree elbow
(N).
15.
Connect electrical connectors (P) to solenoids (B).
16.
Using 7/16 inch wrench and 7/16 inch socket, install nut and screw (Q) to secure ground wire (R)
to bracket (E).
WARNING
Never activate smoke generator in a building or closed area or
with personnel near.
17.
Perform smoke screening (TM 9-2350-222-10).
18.
Check system for any possible fuel leaks. Correct leaks as necessary.
19.
Install engine shroud (page 9-3).
End of Task
TA140887
23-35