TM 9-2350-222-20-1-5
HYDRAULIC RESERVOIR LINE FLUID FILTER REPLACEMENT (Sheet 8 of 8)
Install clamp (AG) around tubes (AH) and (AJ).
25.
Install screw and new lockwasher (AK) into
26.
clamp (AG) and reservoir mount.
Using 9/16 inch socket, tighten screw (AK).
27.
Refill hydraulic reservoir with oil and check for
28.
leaks (LO 9-2350-222-12).
Purge hydraulic system of air by raising and
29.
lowering moldboard several times (TM
9-2350-222-10).
End of Task
TA141165
18-63