TM 9-2350-222-20-1-5
HYDRAULIC RESERVOIR FLUID LEVEL GAGE REPLACEMENT (Sheet 1 of 1)
TOOLS: Flat-tip screwdriver
SUPPLIES: Gasket
Traverse turret to gain access (TM 9-2350-222-10)
PRELIMINARY PROCEDURE:
REMOVAL:
By hand, turn and remove rod gage (A)
1.
from reservoir.
Using screwdriver, remove gasket (B) from
2.
cap (C).
INSPECTION:
1.
Inspect rod gage and gasket for defects.
2.
Replace defective parts.
INSTALLATION:
1.
Install gasket (B) into cap (C).
Insert rod gage (A) into reservoir and t u r n
2.
cap (C) onto connector.
End of Task
18-43