TM 9-2350-222-20-1-5
EMERGENCY LIFT CABLES REPLACEMENT (Sheet 3 of 3)
CLEANING AND INSPECTION:
1.
Clean cable (LO 9-2350-222-12).
2.
Inspect for defects in cable.
3.
Replace defective cable.
1.
Put cable end through hole in moldboard rib (A)
and lifting handle (B) as shown.
2.
Position clamp (C) over cable (D) as shown.
3.
Install clamp (C) with eyebolt (E) onto
moldboard.
4.
Using wrench, tighten nut (F) against clamp (C).
5.
Using wrench, tighten nut (G) against clamp
(C).
Position metal tube (H) in rib (A) as shown.
7.
Using tape to measure, overlap ends of cable
about 14-1/2 inches.
8.
Istall four clamps (J) onto cable. Position
clamps about 2 inches apart. Install clamps as
show.
9.
Using socket, tighten eight nuts (K) on four
clamps (J).
End of Task
TA141107