TM 9-2350-222-20-1-4
INSTRUMENT PANEL CLUSTER ASSEMBLY REPAIR (Sheet 20 of 22)
Instrument Panel Wiring Harness Replacement (Sheet 3 of 4)
10. Disconnect two leads (circuit 40) from two panel
lights (M).
11. Loosen receptacle connector retainer nut (N)
and slide back on leads.
12. Remove wiring harness from panel.
INSTALLATION:
1.
Apply silicone compound (Item 32, Appendix D)
to 16 lead connectors of instrument panel
wiring harness.
2.
Place wiring harness in position in panel.
3.
Using fingers, tighten receptacle connector
retainer nut (E) to receptacle connector (B).
4.
Using screwdriver, install four screws and new
(B) to panel.
5.
Using wrench, install nut and new lockwasher
(C) securing harness junction (D) to panel.
Go on to Sheet 4
TA139703
10-147